Part No DN A B C D Minimum bending radius
for tube O.D. (mm) (mm) (inches) (mm) (mm)
CCRXXX 15 12 12 1″ 24 15
CCSXXX 15 16 15 1″ 24 15
CCTXXX 21 18 17 1+1/4″ 31 30
CCUXXX 21 22 19 1+1/4″ 31 30
CCVXXX 28 28 24 1+3/4″ 39 40
CCWXXX 38 35 30 1+3/4″ 49 80
CCXXXX 38 42 38 1+3/4″ 49 80
CCYXXX 54 54 48 2+1/4″ 69 110
XXX is the total lenght of INFINITY hose in cm (multiple lenghts of 10 cm)

INFINITY HOSE with rotalock fitting + brazing inch fitting↑ to top

brazing-rotalock-fitting
Part No DN A B C D Minimum bending radius
for tube O.D. (inches) (mm) (inches) (mm) (mm)
CC1XXX 15 1/2″ 12 1″ 24 15
CC2XXX 15 5/8″ 15 1″ 24 15
CC3XXX 21 3/4″ 17 1+1/4″ 31 30
CC4XXX 21 7/8″ 19 1+1/4″ 31 30
CC5XXX 28 1+1/8″ 24 1+3/4″ 39 40
CC6XXX 38 1+3/8″ 30 1+3/4″ 49 80
CC7XXX 38 1+5/8″ 38 1+3/4″ 49 80
CC8XXX 54 2+1/8″ 48 2+1/4″ 69 110
XXX is the total lenght of INFINITY hose in cm (multiple lenghts of 10 cm)

INFINITY HOSE with rotalock fitting + brazing metric fitting (with safaty clamp) ↑ to top

brazing-rotalock-fitting-safety-clamp
Part No DN A B C D Minimum bending radius
for tube O.D. (mm) (mm) (inches) (mm) (mm)
CDAXXX 15 12 12 1″ 24 15
CDBXXX 15 16 15 1″ 24 15
CDCXXX 21 18 17 1+1/4″ 31 30
CDDXXX 21 22 19 1+1/4″ 31 30
CDEXXX 28 28 24 1+3/4″ 39 40
CDFXXX 38 35 30 1+3/4″ 49 80
CDGXXX 38 42 38 1+3/4″ 49 80
CDHXXX 54 54 48 2+1/4″ 69 110
XXX is the total lenght of INFINITY hose in cm (multiple lenghts of 10 cm)

INFINITY HOSE with rotalock fitting + brazing inch fitting (with safaty clamp)↑ to top

brazing-rotalock-fitting-safety-clamp
Part No DN A B C D Minimum bending radius
for tube O.D. (mm) (mm) (inches) (mm) (mm)
CDIXXX 15 1/2″ 12 1″ 24 15
CDJXXX 15 5/8″ 15 1″ 24 15
CDKXXX 21 3/4″ 17 1+1/4″ 31 30
CDLXXX 21 7/8″ 19 1+1/4″ 31 30
CDMXXX 28 1+1/8″ 24 1+3/4″ 39 40
CDNXXX 38 1+3/8″ 30 1+3/4″ 49 80
CDPXXX 38 1+5/8″ 38 1+3/4″ 49 80
CDQXXX 54 2+1/8″ 48 2+1/4″ 69 110
XXX is the total lenght of INFINITY hose in cm (multiple lenghts of 10 cm)

Brazing fitting assembling instructions↑ to top

Once the copper tube of suitable diameter has been fitted in the brazing fitting, heat the two ends until the filler material begins to melt. Continue the brazing around the whole circumference of the brazing fitting.
1
2
3
Insert the copper tube Heat the two ends Start brazing around the whole circumference

Rotalock fitting assembling instructions↑ to top

1
2
3
Position the fitting near the male coupling Screw the fitting thread onto the male fitting, clockwise by hand for the first few turns Screw on fully in a clockwise direction using spanners and counter spanners